Lennox nomenclature model number.

Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. 11/10. 506525−01.

Lennox nomenclature model number. Things To Know About Lennox nomenclature model number.

How do I tell the age of a Lennox furnace from the serial number? Saturday, January 11, 2020. The second two numbers of the serial number are the year of manufacture, so the data plate for the Lennox furnace shown below indicates it was produced in 2013. ... Park Model Homes. Site. Shingle Roofs. Safety. Stucco. Remodeling. Wind Mitigation ...Solar. SunSource® Commercial Energy System5. Factory. Field. Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1-800-4-LENNOX ©2019 Lennox Industries, Inc. (14G47) 2/19 PC92164. 92164_energence_RTU_qr_guide.indd 2. 3/4/19 9:30 AM. What Is Lennox Serial Number Nomenclature? Lennox furnaces have a serial number that indicates the model, year of manufacture, and date of manufacture. For example, a furnace with the serial number D341209-878 would be a 34SEP09 manufactured on Sept. 12th, 2009. %PDF-1.6 %âãÏÓ 25503 0 obj > endobj 25918 0 obj ]/Info 25502 0 R/Filter/FlateDecode/W[1 3 1]/Index[25503 497]/DecodeParms >/Size 26000/Prev 3598394/Type/XRef ...MODEL NUMBER IDENTIFICATION CB X 27 UH - 036 - 230 - 6 - 01 Unit Type CB = Air Handler Refrigerant Type Refrigerant Metering Device X = R-410A Series Nominal Cooling Capacity - Tons 018 = 1.5 tons 230 = 208/230V-1 phase-60hz 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 042 = 3.5 tons 048 = 4 tons 060 = 5 tons 2 = Fixed Orifice 3 = TXV - Bleedport ...

Lennox® packaged units come appointed with: A packaged unit is your all-in-one solution that delivers gas heating for cold weather and electric cooling for hotter days. Compact footprint that allows for quick installation and seamlessly blends with your outdoor environment. Consistent temperature and reliable cooling comes standard thanks to a ...click anywhere on this page to return to lennox hvac information at inspectapedia.com. il il il o 88888 . condensing tm-rs chs 21411-1?) 41 hs 21 - high sde streight cool high side heat ... lennox industries model number chart air handling (cb 31 w-41-1p) cb31mv41- p voltage 1 phase -60 ez g 3 phase - 60 minor revision number ca?acity sae as ...

ML195UH. MERIT®SERIES. Upflow / Horizontal. Bulletin No. 210591 March 2019. Supersedes September 2018. AFUE - 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons. MODEL NUMBER IDENTIFICATION. ML 1 95 UH 070 X P 36 B. Unit Type ML = Merit®Series Stages 1 = One-Stage Nominal Gas Heat InputBlower.

Energence® Packaged Electric / Electric 26 to 44 kW 50 Hz / Page 2 Lennox’ Energence® packaged rooftop unit product line was created to save energy with intelligence by offering some of the highest energy efficiency ratings available with a powerful, easy to use unit controller. This makes EnergenceModel Number Identification M WM A 012 S 4 - 1 P Unit Type WM = Wall-Mounted Non-Ducted Unit Series Type M = Mini-Split Voltage L = 115V-1 phase-60hz P = 208/230V-1 phase-60hz WALL-MOUNTED INDOOR UNITS Cooling Efficiency S = Standard Efficiency Major Design Sequence A = 1st Generation B = 2nd Generation Nominal Cooling Capacity 009 = .75 tonsMar 18, 2019 · A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons. Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is rated at 2.5 tons. Model/Part # : ZGA060S4B. Product Unavailable Please call 1-877-570-0123 for more information. Print. Quantity: Add to Cart ... I have a Lennox Customer Number.The year of manufacture of a Lennox ductless mini-split is at the 12th digit in their long serial number on the data plate. So, be ready to count carefully to locate it. The one shown below was manufactured in 2017. These units are imported from China and distributed by Lennox in the U.S.

MODEL NUMBER IDENTIFICATION LcC240 S 2 B N 1 Y Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family ... Lennox was the first HVAC manufacturer to win this award and has been a four−time recipient since 2003. ISO 9001 Registered Manufacturing Quality System.

Model/Part Number LGH036H4ES Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255149409 ... I have a Lennox Customer Number.

Lennox (NYSE: LII) is a leader in energy-efficient climate-control solutions. Dedicated to sustainability and creating comfortable and healthier environments for our residential and commercial customers while reducing their carbon footprint, we lead the field in innovation with our cooling, heating, indoor air quality, and refrigeration systems.Page 1 ©1996 Lennox Industries Inc. Corp. 9503−L1 12ACB Service Literature Revised 01−2002 12ACB SERIES UNITS The 12ACB is a residential split-system condensing ... Model No. 12ACB42 12ACB48 12ACB60 Net face area sq ft (m 2) Outer coil −1 15.21 (1.41) −2 15.11 (1.40) 21.11 (1.96) 21.11 (1.96) Condenser CoilModel/Part Number KCA092S4BN Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255146286 Product Voltage 460v 3ph 60 hz Size/Dimensions 48x60.5x101.5 Horsepower. 2 . Blower Type or Drive # ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...I checked the lennox docs. if it was a 13,000 btu model the model number should be CGS16-013. so I think there is a typo in the model number or it was written down correctly. why don't you get the capacity from the compressor sizes and the TXVs. This should give you a close estimate. That should be a GSC16-1353-270-7Y.Lennox model numbers 14= 1 ton 21= 1-1/2 ton 26= 2 ton 31= 2-1/2 ton 41= 3 ton 46= 3-1/2 ton 51= 4 ton 65= 5 ton So, your unit is a two ton model. The HS stands for high side, HP for heat pump. The next two numbers are the series of unit, they generally work up as they introduce new models. Then a dash and the next two digits which are the ...Model No. CHA16024 CHA16030 CHA16−036 CHA16−048 CHA16−060 Ceiling Diffusers − Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed StepDown − double deflec tion louvers RTD9−65 − 67 lbs. (30 kg) flow),

Model Number Identification 2 HP 13 B 24 P - 1 A HP = Heat Pump 13 = 13 SEER Nominal B = Wire Coil Guard Nominal Capacity 24 = 24,000 Btuh 1 = Major Revision Code 2 = R-22 A = Minor Revision Code Electric P = 208-230v/60Hz/1Ph Model No. 2HP13B18P-1A 2HP13B24P-1A 2HP13B30P-1A 2HP13B36P-1A 2HP13B42P-1A 2HP13B48P-1A 2HP13B60P-1A40+ years of Trane serial numbers: This page explains or decodes seven Trane serial number styles, making the date lookup very easy for any year going back to the 1970s.The numbers were/are used on ACs, heat pumps, furnaces, air handlers and other equipment types. Not Model #s: This post is about Trane serial numbers, not Trane model numbers that have nomenclature related to the series, size ...See full list on thedailythrive.org Model No. Suction Evaporator LSA072C 89K83 93K76 LSA090C 79K90 93K77 LSA120C 89K84 93K78 FIELD INSTALLED Thermostat - Thermostat is not furnished with unit and must be ordered extra. - See Thermostats bulletin and Lennox Price Book. Hail Guard Protection - Heavy duty field installed coil guard protects coils from damage. - LSA072C uses (86K90).MODEL NUMBER IDENTIFICATION 75 Minor Revision Number GCS P Unit Type GCS = Packaged Gas Heat/Cooling Unit 036 1 Cooling Capacity Tons (kW) 024 = 2 (7.0) 030 = 2.5 (8.8) ... NOTE − Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.MODEL NUMBER NOMENCLATURE. HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual …

MODEL NUMBER IDENTIFICATION. XP14 - 2 to 5 Ton Heat Pump / Page 2 ... NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. XP14 - 2 to 5 Ton Heat Pump / Page 4 REFRIGERATION SYSTEM (continued) High Pressure Switch

The ML17XP1 offers energy efficiencies of up to 18.60 SEER and 10.60 HSPF, equivalent to 17.00 SEER2 and 8.50 HSPF2, delivering comfort and energy savings at a more affordable price.Condensate Drain Heat Cable Kits. − Selflimiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. − Available in 6, 24 or 50 ft. (1.8, 7.3, or 15.2 m) lengths. − See specifications table for order number. Heat Cable Tape: − 66 ft. (20 m) length, 1/2 in. (13 mm) wide fiberglass.Approvals — Condensing units have been tested in the Lennox Research Laboratory environmental test room and rated in accordance with ARI Standard 210/240-94. In addition, units have been sound rated in the Lennox reverberant sound test room in accordance with test conditions in included in ARI Standard 270-95. Condensing units# ˙#% # .# +$ 5%%6 ˇ˚˘ˆ 77˚˝ ˘7 859:6 99;9 5896?9; < ! # = +> ! 5< %6 77 ˚ 5< $#( 6 9?@;? 58@a6 ˚ ˚ ˚ 5< $#( 6 = ˘ =˘ 5# $ #( 6 5@86 b5c?86Lennox Industries Inc. P.O. Box 799900 Dallas, TX 75379-9900 NOTE - This manual must be left with the equipment user. WARNING. Do not set thermostat below 60°F (16°C) in heating mode.Settingthermostat below 60°F (16°C)reduces the number of heating cycles. Damage to the unit may occur that is not covered by the warranty. APPENDIX 7.2. DECODING OF MANUFACTURER MODEL NUMBERS. The Department used manufacturer model numbers, among other furnace characteristics, to determine nominal airflow capacity. Manufacturers often code furnace specifications into their model numbers. This appendix illuminates the furnace specifications from manufacturer model numbers. Model/Part Number ZGA060S4B Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255149941 Product Voltage 208/230v 3ph 60 hz Size/Dimensions 37x47.25x76 ... I have a Lennox Customer Number. I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...

Lennox DMS1 Nomenclature MODEL NUMBER CAPACITY BTUH EVMS1-95V evaporator - HS6-953V Condensing unit 93,000 EVMS1-135V evaporator - HS6-953V Condensing unit 100,000 EVMS1-125V evaporator - HS6-1353V ... Microsoft Word - Lennox_DMS1_Nomenclature.doc Author: shawnn Created Date:

Up to 5 ports depending on outdoor unit model MWMA009 Shown Up to 5 ports depending on outdoor unit model Indoor unit type may vary L1 L2 208/230V Outdoor Unit Terminal Block MPB048S4M shown Liquid and vapor line service and shut off valves IMPORTANT - Condensate drain line must always be located at the bottom of the bundle.) Figure 1. Typical ...

MODEL NUMBER IDENTIFICATION RESIDENTIAL PRODUCT SPECIFICATIONS Ratings Revision Level (NOTE - 018-024-030-036-042 models only) Regional Standards ... NOTE - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPLICATIONS • 1.5 through 5 tonsModel/Part Number LGH072H4BM Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255149246 Product Voltage 208/230v 3ph 60 hz Gross Weight. 781 LB. Cooling Capacity. 6.0 Ton Cooling . Heating Capacity ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...Photo Examples of ICP Serial Numbers with Dates. Comfrotmaker A/C - 48th Week of 1992. Comfortmaker Furnace - 5th Week of 1992. ICP Commerical Rooftop Unit - 35th Week of 2005. ICP A/C - 48th Week of 2003. ICP A/C - 17th Week of 2005. ICP A/C - 41st Week of 2008.At every turn, the ML296V gas furnace is designed to be the most energy-efficient furnace in its class. A variable-speed fan keeps temperature swings to a bare minimum. Two-stage heating saves gas by adjusting the flame size based on demand. Energy-Efficient Design - With a 96% efficiency rating, the ML296V gas furnace uses 2/3 less energy than ...Lennox® packaged rooftop units represent some of the most innovative technology in the market. Combining industry-leading efficiency with fast, easy installation and service, Lennox continues to offer reliable systems that deliver exceptional comfort in commercial buildings. ... Model L™ Tonnage. 3-25 TONS. SEER/IEER. Up To 22.5/23.3. EER ...3.1 Model Numbering Systems Introduction All Lennox product is set up with a systematic coding system for both model numbers and serial numbers. Unit model number (including any dash ... tonnage to the Btuh capacities found in model numbers. Old Nomenclature BTU = TONS BTU = TONS -14 = 1 ton -95 = 7½ tons -21 = 1½ tons -135 = 10 tonsNOTE — Due to Lennox' ongoing committent to quality, Specifications, Ratings and Dimensions subject to change without notice. 1994 Lennox Industries Inc. ... CHP16H-261 model is available with single phase voltage. The CHP16-413-513-653 models are available with a choice of thermostat ... number of guards are furnished per order number. ...Lennox model number nomenclature - Inspecting HVAC Systems - InterNACHI®️ Forum. Specific Inspection Topics Inspecting HVAC Systems. sfetty …

Subject: Image Created Date: 7/1/2008 3:32:44 PMMODEL NUMBER NOMENCLATURE. HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual …Application Capacity. Application Capacity is capacity associated with a nominal 10°F TD, 25°F/-20°F SST application condition historically established to successfully size equipment and components to satisfy a heat load, net of all influences, in an application. Enter your legacy model number. Lookup New Equivalent Model.Number of rows 3 3 3 3 Fins per inch (m) 14 (551) 14 (551) 14 (551) 14 (551) Condensate Drain − number & size (1) 1 in. NPT coupling Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head 3 Indoor Blower and Drive Selection Nominal motor output 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW)Instagram:https://instagram. navy female prt standards 30 34does penn foster have a graduation ceremony 2023ucf summer 2024 registrationfuneral homes in milledgeville georgia Removeable cover provides easy access. Dimensions (H x W x D) : 7 x 7 x 4 in. Step−down Transformer (575V Applications) 460V−3 phase units can be used in 575V applications. 575V electric heaters are shipped with a 575V to 460V step−down transformer. If no electric heat is used, order a 575V Step−down Transformer Kit. ahsoka x anakin fanfictionephemeris 2024 Quality Parts & Supplies. LennoxPros has 1000s of HVAC Parts and Supplies from adapter curbs to welding equipment. Give LennoxPros.com a try or stop by a Lennox Store location near you. Shop Parts & Supplies. Find Lennox OEM repair parts fast. Our Repair Part Finder lets you search by model number, part number, serial number or catalog … breezeline support remote control tech.lennoxintl.comApplication Capacity. Application Capacity is capacity associated with a nominal 10°F TD, 25°F/-20°F SST application condition historically established to successfully size equipment and components to satisfy a heat load, net of all influences, in an application. Enter your legacy model number. Lookup New Equivalent Model.Summary of Contents for Lennox GCS16-240 Page 1 See unit nameplate for manufacturer and address. 504,502M 8/2002 Supersedes 10/2001 GCS16-072, 090, AWARNING 150, 180, (6, 7-1/2, 10, 12-1/2, 15, 20 TON) ROOFTOP UNITS GCS16-090, 120, 150 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL TeChnical AND RETAIN FOR FUTURE REFERENCE blications Lithe U.S.A.